SpotNet Distribution back     home       
      
 

Run-off and burn through/ignition test results

Independent Secondary Protective Clothing tests have been conducted by Indalloy Casting Group of Ontario, Canada. Indalloy is a division of Indalex Ltd, North America's and one of the world's largest suppliers of aluminium extrusion components and services. Their tests found as follows:

A stand was set up consisting of a thin painted steel sheet angled at 65° and running into a steel pit sow.

Run-off Test

For the run-off tests the sample was draped over the steel sheet and approximately 0.5 kg of molten aluminium at approximately 1350°F (732°C) was poured over it.

Material Weight Metal Adhered
To Fabric
Ignited Paint
Scorched
Comments
Fire Tough/Smelter Sockn/aNoNoNoMaterial
discoloured - light

Burn Through/Ignition Test

For the burn through/ignition tests the material was placed in the steel pit sow and approximately 0.5 kg
of molten aluminium was poured on and allowed to sit until the material ignited or burned through.

Material Weight Burn
Through
Ignited Time For Burn
Through or
Ignition
Comments
Fire Tough/Smelter Sockn/aYesNo>5 secondsMelted through -
resisted melt through


 
 
 
Back
Back
HOME
Home
TOP